22 AVANTI Work Cage for Wind Turbines
Transportation of people in AUTOM. mode is
forbidden.
6.1 Entry and exit
To ensure safe entry and exit:
a) Lower the work cage onto the access plat-
form until the contact plate is activated and
the cabin stops, or: bring the lift to a height
corresponding to the correct level for exiting
from the wind turbine’s platform.
b) Open the door and exit/enter the lift through
the door/over the cabin railing.
6.2 Stop/EMERGENCY STOP
a) Release the direction selector; the work cage
should stop
If it does not:
b) Push the EMERGENCY STOP switch, and all
controls should be disabled. Open the door
and enter/exit the lift through the door/over
the cabin railing.
6.3 Normal operation
a) Turn the red EMERGENCY STOP switch on
the control box clockwise and the switch
should pop out (Fig. 13 page 19). Do likewise
with EMERGENCY STOP fixed (Fig. 9
page 17).
b) To go up or down, push and hold the direc-
tion selector in the relevant direction.
c) To place work cage on floor after the bottom
safety stop has stopped the lift.
- Turn override bottom safety stop switch
(Fig. 6 page 16) clockwise and hold.
- Push DOWN button until the work cage
rests on the floor and let go.
6.4 Automatic
Only in work Cages with function AUTOMATIC
installed.
a) Push EMERGENCY button on pendant con-
trol. Turn HAND/AUTOM. switch on power
cabinet to activate automatic operation.
b) Close door.
c) Push UP or DOWN button respectively and
the cabin starts ascending/descending.
d) Remove pendant control from holder.
e) Return HAND/AUTOM. button to HAND.
6.5 Remote operation
a) On the electrical control box switch the
HAND/AUTOM. switch to hand (fig. 7).
b) On top of the remote operation receiver
switch the device on (fig. 9).
c) For ascending push upward arrow on remote
operation transmitter.
d) For descending push downward arrow on
remote operation transmitter.
e) Once the operation is complete, switch the
remote operation function off.
6.6 Lifting force limiter
a) In case of an overload, the lift’s upward
travelling should be blocked, and a buzzer
should sound in the connection cabinet.
CAUTION!
Attempting to go up in an
overloaded lift is prohibited!
b) Remove enough of the load to make the
buzzer stop and enable upward travel.
WARNING!
On entering and starting the lift, the
buzzer may sound briey.
This is due to temporary load peaks
occurring as the lift takes off.
The control box is designed not to activate the
buzzer or stop the lift because of peak loads
caused by the cabin swinging.
If the problem persists have an AVANTI expert
adjust the overload limiter (Appendix A
page 49).