Avanti CF103 User Manual Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
User’s Manual 31
13. Ordering spare parts
Fig. 21
Rating plate on
the work cage back frame
Information signs
Operating instructions inside the lift
QUICK GUIDE – Work cage SHARK
s /NLYPERSONNELTRAINEDTOUSETHEWORKCAGEMAYOPERATETHISSYSTEM
s "EFOREUSINGTHEWORKCAGECAREFULLYREADANDOBSERVEALLOPERATINGINSTRUCTIONS
(For details, see User’s Manual and Installation Manual)
Pendant control Safety brake
Emergency
stop
Up
Down
Brake leaver
To open the brake
1. Losen the Safety brake wire
by taking work cage up.
2. Press down Safety brake
leaver until brake
disengages.
Stop button
Inspection window
Flywheel must turn during work
cage operations.
Traction hoist
Brake leaver
insertion point
Insert brake
leaver into
insertion point and
pull upwards for
descent.
Hand wheel
For taking lift up
manually.
Down
1. Losen the Safety brake.
2. Insert brake leaver into
break leaver insertion point
and loosen motor brake by
slowly pulling upwards.
Up
1. Mount hand wheel on top
of the traction hoist.
2. Losen motor brake
using the brake leaver
(see above) while turning
the hand wheel counter
clockwise.
Manual operation
45541105 – Quick guide EN / UL
QUICK GUIDE – Work cage SHARK
s /NLYPERSONNELTRAINEDTOUSETHEWORKCAGEMAYOPERATETHISSYSTEM
s "EFOREUSINGTHEWORKCAGECAREFULLYREADANDOBSERVEALLOPERATINGINSTRUCTIONS
(For details, see User’s Manual and Installation Manual)
Pendant control
Traction hoist
QUICK GUIDE – Work cage SHARK
s /NLYPERSONNELTRAINEDTOUSETHEWORKCAGEMAYOPERATETHISSYSTEM
s "EFOREUSINGTHEWORKCAGECAREFULLYREADANDOBSERVEALLOPERATINGINSTRUCTIONS
(For details, see User’s Manual and Installation Manual)
Safety wire
Drive wire
Emergency top limit STOP switch
Top limit STOP switch
Work cage SHARK Sliding door Work cage SHARK Double door
Wire guide
Guide wire
Bottom safety
stop bar
Bottom safety
stop switch
Emergency stop
13.5 Rating plate/information signs13.1 Wire/ropes
In addition to the item number and name of
the spare part, always state the traction hoist
type, wire diameter and production number!
13.2 Motor and brake
In addition to the item number and name of
the spare part, always state the motor type
and the type and coil voltage of the brake!
13.3 Electric control
When ordering spare parts or making requests,
always state the electricity category and wiring
chart number. See the rating plate at the con-
nection cabinet. There is a wiring chart in the
connection cabinet and in the motor terminal box.
13.4 Safety brake
In addition to the item number and name of the
spare part, always state the safety brake type,
the wire diameter and lift serial no.
A spare parts list is available from the
supplier or directly from AVANTI.
Verify the completeness and legibility of all
rating plates/information signs (see Fig. 21).
Replace missing or illegible plates/signs!
MATERIALE: 3M 7980 hvid polyesterfolie
sort -
SL 021gul
17, 36 punkt
FARVE SPECIFIKATION:
FONT SPECIFIKATION:
STR (CAD):
ABC 123
EKS:
CAUTION
Before using, check all parts for proper function and damage
to component parts. Do not use a damaged or improperly
functioning work cage.
A work cage exposed to excessive heat, as in the case of
fire, should be immediately removed from service and
destroyed due to loss of structural strength.
Do not permit oil, grease or slippery material to accumulate
on climbing or gripping surfaces.
The work cage is designed with rated work load of 533 lbs
(240 kg). The total combined load of each worker and all
materials should not exceed the rated working load. Do not
overload.
Do not allow unstable objects, such as barrels, boxes, tools
and debris to accumulate on the work surface.
Do not use a ladder or other device on a work cage to gain
greater heights.
Do not ride on top of the work cage. Tools, materials, and
equipment should not be stored on top of the work cage.
Do not apply impact loads to a work cage.
Do not use acids or other corrosive substances on or in a
work cage without consulting the work cage manufacturer for
specific instructions.
Scaffold and tools shall not be allowed to contact
unprotected, energized electrical lines or equipment. Maintain
a minimum safe distance of at least 10 ft. (3 m). Consult the
power company to shut off power or insulate/relocate the line
if working closer than 10 ft.
Before using, refer to manufacturer’s instructions.
Never attempt to straighten a deformed side rail or decking
member.
45541085
FORBEHOLDT SETIKET
CAD NAVN:
Helvetica Neue medium/ital.
FONTNAVN(E):
FARVE: SPEC:
Avanti Stigefabrik A/S
TLF.: 48249024
3400 Hillerød
Høgevej 19
C01-0423
-
Setiket label System C01 - UL instruction
31.07.07
C01-0423
45541085
KOPIERET ELLER OVERGIVET TIL TREDIE PART UDEN VORES SKRIFTLIGE TILLADELSE.
GODKENDT SETIKET:
!! MÅ KUN ÆNDRES I CAD-SYSTEM !!
DENNE TEGNING TILHØRER SETIKET A/S. DEN MÅ IKKE BLIVE BRUGT AF,
QF.2008-0
B
A
-
-
-
INIT:
HF
ORIGINAL TEGNING
ÆNDRING:
DS/ISO 2768-m
ALLE MÅL I MM
HVOR INTET ANDET ANGIVET
-
_
REV.
SKALA: 1:1
GEN. TOLERANCE:
DATO: INIT: DATO:
TEGNET:
SIDE 1 ER FØLGEBREVSIDE 2 AF 2
Setiket A/S
DK-6715 Esbjerg N
Tel. +45 76 14 76 00, Fax +45 76 14 76 01
REV.
AI
SETIKET TEGNINGNR.
UNDERSKRIFT:
GODKENDTIKKE GODK.
TEKST / TITEL:
KUNDE:
(sæt X): (sæt X):
®
KUNDE GODKENDELSE:
KUNDE P/N:
SETIKET P/N:
DATO:
equipment should not be stored on top of the work cage.equipment should not be stored on top of the work cage.
Do not apply impact loads to a work cage.Do not apply impact loads to a work cage.
Do not use acids or other corrosive substances on or in aDo not use acids or other corrosive substances on or in a
work cage without consulting the work cage manufacturer forwork cage without consulting the work cage manufacturer for
specific instructions.specific instructions.
Scaffold and tools shall not be allowed to contactScaffold and tools shall not be allowed to contact
unprotected, energized electrical lines or equipment. Maintainunprotected, energized electrical lines or equipment. Maintain
a minimum safe distance of at least 10 ft. (3 m). Consult thea minimum safe distance of at least 10 ft. (3 m). Consult the
power company to shut off power or insulate/relocate the linepower company to shut off power or insulate/relocate the line
if working closer than 10 ft.if working closer than 10 ft.
Before using, refer to manufacturer’s instructions.Before using, refer to manufacturer’s instructions.
Never attempt to straighten a deformed side rail or deckingNever attempt to straighten a deformed side rail or decking
member.member.
4554108545541085
MAX
533 lbs
(240 kg)
Max. 1 person
Please Read and Understand
Cautions and Instructions of “User Manual”.
Please Observe the Following Safety Precautions.
WORK CAGE
AS TO LOAD CAPACITY ONLY
12XZ
CAUTION: Only personnel trained to use the work cage
may operate this system.
CAUTION: When using the system, bring communication
equipment.
CAUTION: Risk of injury. Acids and other corrosive
substances may severely affect the strength of
metal scaffolding devices. Use extreme care
around such materials and follow instructions.
CAUTION: Risk of electric shock.
Metal scaffolding devices should not be used
where contact may be made with electrical
circuits. Refer to instruction manual.