If these steps do not clarify the cause and remedy the fault:
Consult a qualified electrician or contact the manufacturer.
DANGER!
Unplug the power
supply before
opening the power
cabinet.
Break-down Cause Remedy
DANGER!
Irresponsible behaviour
threatens the system’s
safety!
D1 The work cage has encountered Carefully take the work cage up and
or is stuck on an obstacle. remove the obstacle.
Test the operational safety of affected
platform components.
Inform the supervisor.
.
D2 Either of the two safety brake
devices is holding the
work cage on the wire.
a) Excessive hoist speed a) + b) Take the work cage upwards to
b) Too low release speed on relieve the safety wire.
safety brake. Open both safety brake by pressing
the handle, and test its function as
specified in section 5.6 on page 20!
Functional test when the lift is
back on the ground: Replace
the hoist and safety brake and
return them for testing.
DANGER!
A defective safety brake
will threaten the safety of the work cage!
Replace immediately!
D3 Fault in down controller circuit Insert brake leaver in
on traction hoist the traction hoist and
lower lift manually.
(See details in section 7)
Test, and if necessary
have connections,
wiring, and relays
repaired.
E The lamp is defective Have an electrician replace the bulb.
Comments to this Manuals