Avanti CF103 User Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
30 AVANTI Work Cage for Wind Turbines
Fig. 18 Wire diameter
Fig. 19
Wire strap/loop,
which cannot be
unwound
Loop knot forming
when a wire loop is
pulled tight
Bends resulting from
inappropriate treatment
(e.g. securing the load
with the wire)
Damage resulting from
crushing, squeezing,
running over, etc.
Wire bags
Loop formation
12.1.5 Overload limiter/information
signs
Annual test:
Test switches as specified in User’s Manual
section 5.3 and 5.4. (page 18 ff.)
Perform overload test as specified in Installation
Guide section 4.c) page 48)
Verify completeness and legibility of all rating
plates and information signs. Replace missing
or illegible plates and signs!
12.2 Repairs
Repairs to traction hoist equipment may ONLY
be performed by the manufacturer or a hoist
service centre, and only using original spare
parts.
If the gearbox oil needs to be replaced, use one
of the lubricants specified in the following table,
corresponding to the temperature range in
which the traction hoist equipment is used.
Amount required:
traction hoist LE500P: 1.4 l.
See table 4.
Temperature 5ºF to 176ºF -31ºF to 104ºF
range (-15ºC to 80ºC) ( -35ºC to 40ºC)
Synthetic oil
API specification CLPPG or CLPPG or
PGLP ISO VG 460
1)
PGLP ISO VG 100
Oil specifikation Klübersynth Klübersynth
GH6 460 GH6 100
Use of other synthetic oil only with
approval by AVANTI.
1)
Standard filling
Table 4
Fig. 20