60 Appendix B
Test report of annual inspection
Only for work cages in wind turbines
Date of testing:
Oper. hours counter:
For each position check „ = o.k.” or „ = Defect“.
All defects must be described in the Defects Report!
1. Traction hoist o.k. Defect o.k. Defect o.k. Defect o.k. Defect
1.1 Visual inspection
1.2 EMERGENCY lowering
2. Safety brake o.k. Defect o.k. Defect o.k. Defect o.k. Defect
2.1 EMERG. STOP switch
2.2 EMERG. STOP reset
2.3 Wire acceleration test (hand)
3. Second safety brake o.k. Defect o.k. Defect o.k. Defect o.k. Defect
3.1 EMERG. STOP switch
3.2 EMERG. STOP reset
3.3 Wire acceleration test (hand)
4. Work cage o.k. Defect o.k. Defect o.k. Defect o.k. Defect
4.1 Doors
4.2 Weld seams/screws
4.3 Wire guide wheels
5. Suspension/Wires/Cable o.k. Defect o.k. Defect o.k. Defect o.k. Defect
5.1 Suspension
5.2 Drive wire
5.3 Safety wire
5.4 Guide wire and
5.5 Attachment
5.6 Power/Control cable
6. Control/limit stop switch o.k. Defect o.k. Defect o.k. Defect o.k. Defect
6.1 EMERG. L. STOP reset
6.2 UP-/DOWN travel
6.3 Oper./Emerg. limit stop
6.4 Bottom stop
6.5 Override bottom stop
6.6 Door stop switch
6.7 Pendant ctrl. holder switch
6.8 Overload test (Buzzer!)
6.9 Overload limiter adjusted No Yes No Yes No Yes No Yes
Tested by
Signature
www.avanti-online.com P: (+45) 4824 9024
Lift no.
Location Turbine no.:
Oper. respons.
Traction hoist Type: LE500P Load capacity: Equipm. no.:
Electrical control box G8620.181 Wiring chart no.: Serial no.:
Safety brake Type: Equipm. no.:
Wire Certificate no.: