52 AVANTI Work Cage for Wind Turbines
The drive wire is fastened as described in point
2.6.1 beneath and the safety wire is fastened
in one of three ways described in point 2.6.2,
2.6.3, or 2.6.4.
IMPORTANT!
Before fastening the safety wire carry
out the safety brake test (See Installation
Manual section 4.2) e) page 48).
Fig. 13a Method 2: safety brake safety wire.
Left wire on work cage viewed from the front
Safety wire
Wire lock,
2 pieces
Thimble
Spring
Rigging screw
fork/fork
Eye bolt
Wall anchor
2.6 Securing the drive and safety wire
Fig. 13 Method1: Drive wire contra weight
2.6.1 Drive wire contra weight
An 11 kg weight is mounted approximately
300mm above the floor on the drive wire. Excess
wire is coiled with at least 3 strips (See Fig. 13).
2.6.2 Safety wire
– wedge anchor with spring
Like in point 2.3.1 above the wire is fastened
using a rigging screw with spring (See Fig. 13a).
Mounting safety wire without spring will cause
the safety brake block often. Excess wire is
coiled with at least 3 strips.
• Atwirelengthof60m,tightentherigging
screw so the wire stretches 9 mm.
• Atwirelengthsof100m,tightentherigging
screw so the wire stretches 15 mm.
This will tighten the wire to approximately
400-500 N (88-100 Lbs).